Excellent transformer lamination manufacturer factory: Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference. Find extra information on https://www.canwindg.com/products-20763.
Rising temperature: The capacity of the transformer will decrease as the temperature rises. Therefore, it is necessary to consider the appropriate heat dissipation method and heat dissipation area when designing the transformer to ensure that the temperature rise of the transformer does not exceed the allowable range. Connection method: Different transformer connection methods, such as star, delta, etc., will also affect the capacity of the transformer. For the star connection, the capacity of the transformer can be increased by about 3 times; for the delta connection, the capacity of the transformer is relatively small. Insulation level: The insulation level of the transformer determines the insulation capability and safety performance of the transformer, and also affects the capacity of the transformer. To sum up, the capacity of the transformer is related to factors such as input voltage and output voltage, load nature, temperature rise, connection method and insulation level. When selecting a transformer, it is necessary to comprehensively consider various factors according to the actual situation to ensure the normal operation and stability of the transformer.
Power quality plays a crucial role in the performance and longevity of distribution transformer substation. Poor power quality can lead to increased losses, reduced efficiency, and shorter equipment lifespan. Therefore, effective strategies for power quality management are indispensable for the optimal operation of distribution transformers. Harmonic currents, particularly those of higher frequencies, can significantly affect the performance of transformers. These currents are produced by non-linear loads such as computers, variable speed drives, and certain types of lighting systems, causing distortions in the sinusoidal waveform of the electrical supply.
As one of the best electrical equipment manufacturers & suppliers in China,Canwin specialized in transformer electrical equipment, our electrical equipment including cut to length lines, slitting lines and foil winding machines manufacturing.Electrical equipment mainly used as the iron core of various motors, generators and transformer equipment.Electrical equipment manufacturers and suppliers are currently focusing on sustainability, as global power grids must be updated to accept new forms of renewable energy, as well as IoT and enhanced communications platforms. Regardless of the specific application, electrical equipment is paired with detailed instructions for installation & maintenance and is supported by customer support services to ensure that the machine works as intended.
CANWIN adheres to the business policy of high -end manufacturing, intelligent equipment + intelligent factory, comprehensively improves the quality of products and the cutting speed and precision, accelerates the transformation of development mode, and promotes the upgrading of industrial structure In terms of new product development, the company relies on the “Guangdong university of technology provincial thin plate processing and cutting technology engineering center”as an innovation platform, continuously trains and introduces technological talents, and provides intellectual support for the company to enhance soft power and rapid development.
Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.
A transformer core is a static device that provides a channel for magnetic flux to flow in a transformer. The core is constructed using thin strips of silicone steel. The silicon steel sheets are electrically isolated and coupled to reduce no-load losses in the transformer.The core of a transformer is made of soft iron. Transformers are used in various fields like power generation grid, distribution sector, transmission, and electric energy consumption.
The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. Discover additional info at https://www.canwindg.com/
As a professional laser machine manufacturer & supplier, Canwin specialized in laser machine manufacturing, including laser welding machines and laser cutting machines.Continuous fiber laser hand-held welding equipment is a special equipment for metal processing such as hardware, building materials and handicrafts launched by CANWIN. Small equipment, easy to move and handling, flexible and convenient operation, can realize outdoor welding, suitable for all kinds of complex sheet metal hardware welding. Welding efficiency is fast.
Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.
Impedance voltage (%): Short-circuit the secondary winding of the transformer and slowly increase the voltage on the primary winding. When the short-circuit current of the secondary winding equals the rated value, the voltage applied on the primary side is the impedance voltage. It is usually expressed as a percentage of the rated voltage. Phase number and frequency: Three-phase is represented by S, and single-phase is represented by D. The frequency f of China’s national standard is 50Hz.There are countries abroad with 60Hz (such as the United States).I. Temperature rise and cooling: The difference between the temperature of the transformer winding or upper oil layer and the temperature of the surrounding environment is called the temperature rise of the winding or upper oil layer. The limit value of the temperature rise of the oil-immersed transformer winding is 65K, and the temperature rise of the oil surface is 55K.There are also various cooling methods: oil-immersed self-cooling, forced air cooling, water cooling, tube type, sheet type, etc.